Shikhar 100 – Multifunction Single Phase Meter

Shikhar 100 – Multifunction Single Phase Electricity Meter

1 PHASE DIRECT CONNECTED METER
TYPE: P18-1000 (WITH BLUETOOTH COMMUNICATION)

The Shikhar-100 series of meters are a part of Genus 1 Phase AC Static Direct Connected meter lineup for domestic and commercial applications. This meter consists of a comprehensive array of energy registers phase wise and cumulative-with extensive configurability a user friendly display and aesthetically appealing housing.

METER FEATURES

  • IEC DILMS compliant
  • Four Quadrant Metering
  • Field replaceable battery (Optional)
  • Forwarded Metering and Net Metering (Import, Export)
  • Several configuration options viz, display, alerts, tariffs
  • Internationally localized display by virtue of displaying OBIS codes
  • Intuitive icons on display indicating Quadrant information, alerts, tariffs and others
  • Power quality analysis by harmonic profiling, power interruptions logging, sags and swells
  • IEC or ANSI Optical port for local data downloading
  • RS232/RS485 communication with one RJ11 & one RJ45 ports for daisy chaining
  • 12 billing histories
  • Up to 520 parameter days load survey with 30 minutes integration period
  • Selectable Sliding window or block method for demand calculation with programmable integration period
  • Seasons with 2 day profiles each, 8 tariff slots for each day profile, active and passive calendar with programmable activation date
  • Advanced anti tamper features
  • Bluetooth Wireless Communication with Version 4,2 and later
  • DLMS/COSEM HDLC Communication Profile for Wireless Communication

Shikhar 100

Multifunction Single Phase Electricity Meter

<3>1 PHASE DIRECT CONNECTED METER

How do Single Phase Meters work ?

Static single-phase meters, also known as electronic meters, operate using solid-state components like microcontrollers and digital signal processors. They measure energy consumption, providing accurate readings without moving parts.

What is the accuracy of the Single Phase Energy Meter ?

Single-phase energy meters typically have high accuracy, often specified as a percentage, such as 0.5% or 1%, indicating how close their readings are to the actual energy consumption.

What are the errors of Single Phase Energy Meter ?

Errors in single-phase energy meters can result from factors like temperature variations, voltage fluctuations, or meter aging. Calibration helps minimize these errors.

What is the range of Single Phase Meter ?

The range of a single-phase meter refers to the maximum current it can handle. Common ranges include( 5A-30A) or (10A-60A), depending on the specific application.

What are the features of Single Phase Energy Meter ?

Features may include LCD displays, tamper detection, remote/Local communication capabilities, and load profiling to monitor energy usage patterns

How a Single Phase Energy Meter is calibrated ?

Calibration involves adjusting the meter to ensure accurate measurements. This process is typically performed using standard calibration equipment in controlled conditions.

Which Single Phase Energy Meters are more Accurate ?

Accuracy varies among meters, but electronic or smart meters tend to offer higher precision compared to traditional electromechanical ones.

On which Electrical Effect Single Phase Energy Meter Works ?

Advantages include accurate energy measurement, compact size, and the ability to handle a single-phase electrical system, common in residential and small commercial settings.

What are the advantages of Single Phase Meter ?

Single-phase energy meters measure the amount of electrical energy consumed by detecting the magnetic field produced by the current flowing through a conductor.

What is the working principle of Single Phase Energy Meter ?

A static single-phase energy meter measures electrical energy consumption using electronic components without rotating parts. It typically employs a microcontroller to sample voltage and current, calculates power, and accumulates energy usage over

What are Single Phase Meters ?

Single-phase meters are devices that measure and record the electrical energy consumption in single-phase electrical systems, commonly used in homes and small businesses.

Technical Specification

Connection type Single phase Two wire Direct Connected
Standards IEC 62052-11, IEC 62053-21, IEC 62053-23
Accuracy Class Class-1.0
Rated Voltage 220V, 230V, 240V (+20% to-40%)
Meter Type Indoor/Outdoor
Rated Current 5(100A), and all intermediate values
Starting Current 0.4% lb
Frequency 50 Hz ± 5%
Power Consumption As per IEC 62053-21
Battery Replaceable lithium battery for RTC with supercap backup Display reading during power off
Meter Constant 1000 imp/kWh, 1000 imp/kVARh
Display 7segment 7 digit STN LCD with Backlight
LED indicators 2 nos. (Active Energy and Reactive Energy)
Communication Ports Optical Port IEC 62056-21 or ANSI port RJ11 port for RS485 or RS232 1 nos. RJ45 ports for RS485 or RS232
Communication Protocol IEC62056 DLMS COSEM
Operating Temperature Range -25 °C to +55 °C
Storage Temperature Range -40 °C to +70 °C
Operating Humidity 95%, non condensing
Degree of Protection IP51 & IP54 (optional)
Meter Weight 1 kg
Dimensions (L x W x H) 187.5mm x 132mm x 65mm
Degree of Protection IP51 & IP54 (optional)
Auxiliary Terminals Selectable between

Pulse outputs: 2 nos. (Up to 250V AC/DC, 150mA), In accordance with IEC62053-31

Pulse inputs: 1 nos., In accordance with IEC62053-31

Control inputs: 1 no. (240V AC) Or any combinations (max. 2)

Power Sector Leadership

  • 75+ million

    Electricity meters installed
  • Empanelled
    with all leading utilities
  • 65000 sq mtr

    Integrated manufacturing
  • Research & Development
    Centre recognized by Govt. Of India

Genus Initiates Smart Meter Installation in Uttarakhand for Enhanced Power Efficiency

Genus becomes first and only Indian Company to get BIS certification for Gas Meters