Three Phase SAKSHAM 345

SAKSHAM-345 SMART RESIDENTIAL METER WITH INTEGRATED GSM/GPRS

SAKSHAM-345 is an ideal fit for Advanced Metering Infrastructure (AMI) systems in-tended for load management, multi-rate / Time-of-Use and anti-theft metering of residential and light commercial consumers with Three-phase service connections

Applications

  • Utility
  • Township
  • Industries
  • Municipal Corporations
  • Shopping Complex

SAKSHAM-345

SMART RESIDENTIAL METER WITH INTEGRATED GSM/GPRS

  • Three Phase direct connected smart meter.
  • Class-1 Active and Apparent energy accuracy.
  • Maximum Demand kW measurement.
  • TOU metering with active & passive calendars, each hav-ing two seasons with up to 8-registers and 8 time zones per day.
  • Last 6 months billing history.
  • Last 35 days load profile data and daily energy profile data.
  • Power Quality Information.
  • Voltage sags.
  • Swells, Long power failures, Event logs & Power quality.
  • Transaction events & Relay control.
  • Optical port for local communication based on DLMS/COSEM protocol.
  • Integrated GSM/GPRS modem.
  • DLMS/COSEM based open standard.
  • On demand two-way communication.
  • Scheduled Push to Head End System.
  • Event reporting to AMI server in case of tamper and anomalies.
  • Plug and play deployment.
  • Secured transactions with meter.
  • RTC time synchronization.
  • Peak Load Management (PLM) supports two load limits and local relay control.
  • Remote connect and disconnect.
  • Remote Management and Control if Theft/Pilferage is de-tected.
  • Auto connect in case of load reduction to acceptable limits.
  • Power Quality Management in case of Low/over Voltage etc.
  • SPECIFICATIONS Standards : IEC 62052-11, IEC 62053-21/23,IEC 62054,IS 13779:99
  • Connection Type : Three phase 2 wire direct connected
  • Standards : IS 13779, CBIP-304, IEC 62053-21, IEC 62052-11
  • Metrology Accuracy : Active / Reactive / Apparent Class-1
  • Rated Voltage : 240V (+20% to -40%)
  • Rated Current : Ib(Imax)A = 5(30)A, 10(60)A Withstands 120% Imax
  • Starting Current : 0.2% Ib
  • Frequency : 50 Hz +- 5%
  • Burden Voltage Circuit : 2W / 8VA
  • Burden Current Circuit : <4VA
  • Load Contactor : Latching relay in both phase & neutral Max Current 80A, UC2
  • Display : 10x5mm, STN LCD with Backlight
  • LED indicators : LED Pulse 3200 imp/kWh LED Network status
  • Communication Ports
    • Optical Port IEC 62056-21
    • GSM/GPRS port
    • Integrated GSM/GPRS modem
    • Dual Band 900/1800 MHz
    • SIM Card exchangeable in field
    • External Antenna
  • Communication Protocol : DLMS COSEM
  • Operating Temp. Range : -10 ˚C to +55˚ C
  • Storage Temp. Range : -25˚ C to +70˚ C
  • Operating Humidity : Up to 95%, non condensing
  • Degree of Protection : IP51

Power Sector Leadership

  • 48+ million

    electricity meters installed
  • Empanelled
    with all leading utilities
  • 25000 sq mtr

    Integrated manufacturing
  • Research & Development
    lab recognized by Govt. Of India

Genus to Implement Smart Grid Pilot Project in Naroda, UGVCL

Mr. J K Agarwal , Joint MD, delivered welcome note in Metering India, at New Delhi on 6th & 7th April, 2017